{{ variable.name }}
Product 1
I: Inverter Silent Type
II: Standard Fixed Type
Parameters 2
Parameters | I: Inverter Silent Type |
II: Standard Fixed Type |
|
Whole | Model | HQ1QF-HS1200i | HQ1QF-YH1200A |
Engine | Model | HS1200i.1 | 154F (Vertical) |
Type |
Four-Stroke, Overhead Valve, Single Cylinder, Forced Air Cooling |
Side-Mounted Valves |
|
Placement (cm³) | 53.2 | 97 | |
Bore×Storke (mm) | 43.5×35.8 | / | |
Compression Ratio | 7.6:1 | / | |
Rated RPM (kW/min-¹) | 5300 | / | |
Ignition System |
Full Crystal Electronic Ignition |
Contactless Transistor |
|
Start System |
Manual Recoil Start |
Manual Start | |
Gasoline Type |
Unleaded Gasoline |
Unleaded Gasoline |
|
Lubricating Oil Type | SF 15W-40 | SF 15W-40 | |
Generator | Model | T-HS1000i | YH1200A |
Rated Frequency (Hz) | 50 ▏ 50 | 50 | |
Rated Voltage (V) | 230 ▏ 220 | 230 | |
Rated Current (A) | 3.9 ▏ 4.1 | / | |
Rated RPM (min-¹) | 5300 | / | |
Rated Output Power (kVA) | 0.9 | 0.8 | |
Maximum Rated Power (kVA) | 1.0 | 1.0 | |
DC Output | 12V, 5A | / | |
USB Output | / | / | |
Overload Protection DC (Direct Current) AC (Alternating Current) |
Fuse-Free Overcurrent Protector AC Overcurrent Protection Program Control |
||
Generator Set | Gasoline Tank Capacity (L) | 2.2 | 6.5 |
Continuous Running Time (h) | 3 (Rated Power) | 6 | |
Fuel Consumption Rate (g/(kw.h)) |
≤550 | / | |
Operating Ambient Temperature (℃) |
-15~40 | / | |
Maximum Operating Altitude (m) |
1000 | / | |
※Noise (dB/4m) LWA | 90 | / | |
※※Noise (dB/7m) LPA | 54-59 | / | |
Overall Dimensions (L×W×H) (mm) |
451×242×379 | 480×360×400 | |
Net Weight (kg) | 14 | 26 | |
Standard Implemented |
Q/1300 LHZ002-2013 | / |